Model CR-1525
CR-1525C is 208 Voltage, CR-1525A is 230 Voltage, CR-1525B is 460 Voltage
60 Hz.50 Hz.
Induction Motor 3Ph, 10HP, 3450 RPM 3 Ph, 8HP, 2850 RPM
Voltage 208, 230, 460 190-220/380-415
Amperage 30, 26, 15 17.4-17.2/8.7-8.6
Length 19-9/16
Electrical Service to Unit No. 8, No. 10, No. 14 No. 10/14
Airflow @ 3" Opening 405 C.F.M. 9.5 CMM
Sealed Vacuum 125" H2O 292 cm H2O
Pump Regenerative
RECOMMENDED RELIEF VALVE SETTINGS 90" H2O H2O 188 cm H2O
Dimensions
Length 24-1/8"
Width 18-5/8"
Height 21-13/16"
Shipping Weight 300 lbs.
Inlet Connection 3-1/2" I.D.
Outlet Connection 3-1/2" I.D.


Primary Filter - DC-2530
Filtration Cyclonic funnel primary, standpipe secondary with safety filter.
Inlet and Outlet Connections 3-1/2"O.D.
Capacity 30 Gal.
Diameter 25"
Height 77"
Radius including legs 17"
Shipping Weight 265 lbs.
Replacement Filter FD-2500 (2 Required)
Replacement Bag FD-2530


Secondary Filter - DC-1603
Filtration High efficiency reusable bag filter.
Inlet and Outlet Connections 3-1/2" O.D.
Capacity
Diameter 19"
Height 29"
Shipping Weight 60 lbs.
Replacement Filter FB-1603
* Electrical Service to unit should be installed by a licensed electrician.
NOTE: All commercial and industrial units should use 2-conducters, 18 gauge minimum for low voltage wiring (2VM-18001).
NOTE: Relief Valve should be set at a preferred setting of 90" H2O at 60 Hz. and 188 cm H2O at 50 Hz., when possible use the preferred/recommended settings above.
NOTE: First five feet of exhaust MUST be metal 3-½" O.D. tubing (SF-3075).